Gas Meter Room Requirements Uk

N interior gas piping is complete and connected to the meter bracket.
Gas meter room requirements uk. An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2. Meter compartment a room or cupboard specifically designed to house the meter installation n j u g national joint utilities group regulator a device whose function is to control pressure in a gas stream. 3 0 gas meter and regulator locations continued. 3 7 when located inside the building meters shall be located as near as practicable to the point of entrance of the service and where possible the.
A duct having a cross section area of at least 50 square inches 32 522 mm 2 of free area. Allows any escape of gas to be smelled or otherwise detected by passers by reduces condensation the total effective ventilation area free area shall not be less than 2 of the internal floor area of the housing or its notional equivalent and should be equally distributed and disposed at high and low levels around the outside walls. Maintain a minimum of 5m between any opening from the gas meter room and a flammable storage area filling point or pressure vessel. Maintain a minimum of 3m between any opening from the gas meter room and any gas appliance boiler.
Gas meter room requirements as per these guidelines and multinet technical standards will be discussed and agreed upon notably regarding civil structural hvac lighting signage service route meter room size venting locations door requirements and location. The requirements of this standard must be met when a customer houseline is added to an existing gas meter room or gas meter set within a building. N gas equipment is connected to interior piping and properly vented. Gas meter and regulator installation requirements.
This states that bin rooms should be accessible from the exterior of a building or by way of a protected lobby provided with not less than 0 2 m2 of permanent ventilation. Before requesting a new meter installation please be sure the following items have been completed. Meter box a purpose made glass reinforced polyester moulding to house domestic and small non domestic meters. The location of the gas meter room shall be on.
Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed. Mechanical ventilation to the outside atmosphere is required. The meter guys may be referring to. Natural gas meter requesting a new natural gas meter thank you for choosing national grid.
The room s passive ventilators should be fly and vermin proof and located as near the ceiling and the floor of the room as possible but away from windows of the flats.